You are here:   Products > Energy Management > Power network meters | Analysers | Recorders
Register   |  Login

Contact Details: +353 87 2768099 | +353 45 831575 | info@wpa.ie

Minimize

Power network meter ND20

The ND20 meter is distinguished by a high measurement accuracy, backlit LCD display. The ND20 meter is available with communication options ideal for control and monitoring energy quality parameters in all branches of industry.
 
Measurement of: power network parameters in 4- wire balanced and unbalanced systems, harmonics of voltages and currents (selectively), THD factors for currents and voltage, High accuracy class, indications considering values of programmed ratios, profile of 15, 30, 60-minutes’ power (9000 measurements), watt-hour meter for the selected harmonic, providing information about loss costs in connection with harmonic occurrence.

Outputs:digital transmission to the master system through the RS-485 interface (MODBUS). Configurable analog, alarm and pulse outputs (energy). Backlit LCD 3.5” screen.
IP Rating: IP65.
Electrical Power Quality Analyser

 
Data Sheet

Manual



Single-phase power network programmable digital meter N30P

N30P meter is destined to measure: a.c. voltage, a.c. current, active, reactive and apparent power, cos φ, tg φ, φ, frequency, active, reactive and apparent energy, 15 min. active power, 10 min. voltage, 10 sec. frequency in single-phase power network.

Features
3-colour display - red, green and orange programmable in three intervals of the measured value. 14mm digit hight highlighted measuring units. 4 alarm outputs with signalling by LED diodes, operating in 6 different modes, Conversion of any measured value into a 0/4…20mA or 0…10V analog signal, Storage of minimal and maximal values for all measured quantities, Meter programming from the keyboard or through the RS485 interface by means of free delivered LPConfig software. Parameters which can be reprogrammed are as follows: display colour, individually in three intervals, thresholds of displayed overflows, display precision of the result (decimal point), highlight of the unit, averaging time of the measurement,recounting of indications (individual characteristic).

Input: 0...1A or 0...5A ac| 0...100V or 0...400V ac
Output:  relay (4), analog (1), energy pulse (1), digital RS485/MODBUS (1)
Supply:  85...253 V AC/DC or 20...40 V AC/DC
IP: IP65
External Dimension: 96 x 48 x 64mm


 
Data Sheet

 Manual

Power network meter N14

The N14 meter is a programmable digital panel instrument destined for the measurement of 3-phase, 3 or 4-wire power network parameters, in balanced or unbalanced systems.

Measured value:RMS voltage and current, active, reactive and apparent power, active, reactive and apparent energy, power factors, frequency,mean active power ( e.g. 15-min mean power).

Outputs: RS-485 with MODBUS protocol, alarm – relay, impulse Open Collector, RS-485 interface, ETHERNET (with PD8), INTERNET (with SM6)



Data Sheet

 Manual



Power network meter N13

Power network parameter meter N13 is designed to measure all basic parameters in 3-phase 3-wire or 3-phase 4-wire, balanced or unbalanced power networks, with the simultaneous display of measured quantities and the digital transmission of their values and their conversion into an analogue standard signal. It also enables the control and optimization of power engineering electronic devices. Voltages and currents are multiplied by given ratios of voltage and current measuring transformers. Power indication take into consideration the values of programmed ratios. N13 type meter also indicates in real time. The meter may be configured using buttons or our LPCon software(PD10 converter required).
 
N13 measures the following parameters:
rms a.c. voltage and a.c. current, neutral wire current, active, reactive and apparent power, active, reactive and apparent energy, different power factors, THD for phase voltages (available through RS485), THD for phase currents (available through RS485), frequency, average active power (e.g. 15 min).

The N13 Meter is used in control systems for monitoring of power network parameters
Input: programmable - 100 V, 400 V, 1 A, 5 A a.c.,
Output: relay, analog, digital RS485 with MODBUS protocol
Supply: 85...253 V d.c. or a.c 40...400Hz,
Display: 4 x 4 digits LED, 10mm high, red or green colour.
Dimensions: 96 x 96 x 70.5mm
N13 Electrical Power Quality Analyser 

 
Data Sheet

 Manual



Power network parameter meter N10 and N10A

Power network parameter meter N10 and N10A are designed to measure: network parameters in 3-phase 3 or 4-wire symetrical or asymetrical systems, harmonic up to 25-th for current and voltage, THD factor. These meters ensure measurement and monitoring of 46 electrical quantities like: rms a.c. voltage and a.c. current, active, reactive and apparent power, active, reactive and apparent energy, different power factors, frequency, average active power ( e.g. 15 min). They also enable the control and optimization of power engineering electronic devices. Voltages and currents are multiplied by given ratios of voltage and current measuring transformers. Power and energy indications take into consideration the values of programmed ratios. These meters also indicate in real time.

Meters are used in computer systems e.g. LUMEL-ENERGY program for monitoring of power network parameters.

Input: programmable - 100 V, 400 V, 1 A, 5 A a.c.
Output: 3 relays and 1 analog output (N10 type), 1 relay and 3 analog outputs (+/-) (N10A type), digital output RS485 - MODBUS protocol, 1 passive pulse output,
Supply: 85...253 V d.c. or a.c 40...400Hz,
Display: 4 x 4 digits LED, 10mm high, red or green colour.
Dimensions: 144 x 144 x 77mm

N10 Electrical Power Quality Analyser
 
Data Sheet

 Manual
N10    N10A


ND1 - 3-phase power quality analyser

The ND1 3-phase power analyser is an up-to-date device allowing the user to measure and recording electrical energy quality parameters. It enables to detect interferences in internal industrial electric installations.

Data recorded by the ND1 analyser provides information for costs control systems and optimization of device operation in power energy installations and industrial systems. The ND1 3-phase power quality analysers design combines the function of 5 instruments:  analyser of 3-phase network parameters -universal measuring transducer - recorder of measuring data - web server –  easy remote monitoring of measuring and data archiving via internet browser - controller, automatic control of electric energy key parameters.

Parameters measured according to the EN 50160 standard:
phase voltages U1, U2, U3 and line currents I1, I2, I3
phase-to-phase voltages U12, U23, U31
phase active powers P1, P2, P3
phase reactive powers Q1, Q2, Q3
phase apparent powers S1, S2, S3
active power factors PF1, PF2, PF3
reactive/active power factors tgØ1, tgØ2, tgØ3
mean phase-to-phase voltage US Umf
current in neutral wire and mean 3-phase current IO, IS
3-phase active, reactive and apparent powers P,Q,S
mean 3-phase power factors PF, tgØ
frequency f and frequency deviations
15-minutes’ mean active power PAV
3-phase active, reactive and apparent energy EnP, EnQ, EnS
active, reactive and apparent energy from an external counter EnPz, EnQz, EnSz
THD for phase and current voltages
harmonics of currents and phase voltages up to the 51st
storage of min and max values
recording of drops and voltage decays

Data Recording
Replaceable external  CompactFlash memory  of 4 GB capacity, Data storage in the internal 6 MB buffer with data supporting (before and after emergency states), Recording of  decays and voltage drops acc. to the EN 50160 standard, Recording of selected measured parameters.

User’s Interface - GUI
LCD TFT 5,7”, 320 x 240 pixels color screen, with touch screen panel, Casing protection : IP65, Dedicated visualization in the shape of: digital displays, analog views, bargraphs, harmonic charts, vector diagrams, statistics, logic inputs, Programming of the analyzer visualization ( selection of the measured quantity  and kind of presentation), Contextual help in the user’s configuration menu.

Communication
Ethernet 10 Base-T, Modbus TCP/IP, USB 1.1 Device, RS-485 Modbus Slave.
ND1 - 3-phase power quality analyser
 
Data Sheet

Manual

 


P12P - Programmable Transducer 1-Phase | Energy Meter | Power Analyser

P12P type Programmable transducer is designed to convert single-phase network parameters: a.c. voltage and a.c. current, frequency, active, reactive and apparent power, power factor cosj, active power to reactive power ratio, phase shift angle,active, reactive and apparent energy into a digital or standard current or voltage signal. 

The output is galvanically isolated from the input and supply. The insulation exists also between the current and voltage input. The P12P type transducer has programmable measuring and auxiliary functions. The parameter modification is possible through the PD14 programmer, the RS-485 interface or from the keyboard. The transducer is commonly used in computer systems, e.g. with LUMEL-ENERGY program.
P12P type transducer has a programmable auxiliary function:
Conversion of measuring value into an output signal on the base of the individual linear characteristic
Recalculation on the input quantity into any indication on the base of the individual linear characteristic
Programming of alarm outputs
Signalling of the measuring range exceeding
Recording of any input signal in programmed segments of time or event recording,
Programming of the indication resolution
Preview of all measuring values and set parameter values
Programming of voltage and current ratio
Zeroing of energy counters
Storage of all counter states in case in case of a decay of the supply voltage
Automatic setting of the decimal point
Storage of maximal and minimal values of all input quantities
Programming of the time and kind of measurement averaging: arithmetic mean, walking window
Display of the unit
Service of the RS-485 interface in the MODBUS protocol, both in ASCII either in RTU mode
Data protection by means of a password.

Input: programmable 1 A (X/1 A), 5 A (X/5A), 57,7...690 V, X/100 V
Output: programmable - digital RS-485 MODBUS protocol, analog, 2 relays
Display: LCD 2 x 8 signs
Supply 253 V a.c./d.c. or 20...50 V a.c./d.c.
Available: with display and without display
Dimensions: 45 x 120 x 100mm

P12P type Programmable transducer


Data Sheet
P12P type Programmable transducer datasheets

Manual
P12P type Programmable transducer manuals





P43 - Programmable Transducer for 3-Phase Network Parameters | Energy Meter | Power Analsyer

P43 Programmable transducer for power network parameters is designed for the conversion of 3-phase, 3 or 4-wire power network parameters, in balanced or unbalanced systems.

Inputs signals:
Current: 1A or 5A
Voltage: 100V or 400V
Outputs:
4 relays (signaling measured quantity overflows), without analog outputs, 2 relays, 2 analog outputs
4 analog outputs, without relay outputs, Pulse output (control of 3-phase active energy consumption), RS-485 and USB interfaces with Modbus protocol, Built-in memory for the 15 minutes’ power profile, Storage of maximal and minimal values, Galvanic isolation, Programmable current and voltage transformer ratios, Transducer programming realized by means of a free delivered LPConfig software.
Overall dimensions: 90 x 120 x 100 mm.
p43 transducer of power network parameters


Data Sheet
p43 transducer of power network parameters datasheets
 Manual