You are here:   Products > Machine Safety > Safety Relays | Interface
Register   |  Login

Contact Details: +353 87 2768099 | +353 45 831575 | info@wpa.ie

Minimize

Safety Relay | eSAFETY RELAY FOR LIGHT CURTAINS | ADSR1 - TYPE 4 / PL

Type 4 Safety Relay which, connected to the two safe static outputs of the barriers ADMIRAL, allows optional

features like the manual restart and the final switching devices monitoring (FSD)
Conforming to:

- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery
- Electro-sensitive protective equipment
- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery
- Electro-sensitive protective equipment
– Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery
– Safety-related parts of control systems
– Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery
– Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components.  
Safety Relay


 




Safety Relay | ADSRM - TYPE 4 / PL eSAFETY RELAY FOR LIGHT CURTAINS WITH MUTING FUNCTION


 Type 4 Safety Interface which, connected to the two safe static outputs of the Admiral or Vision light curtains, offers 2 NO safety relay outputs, plus optional features as the manual restart, the final switching devices monitoring (FSD) and the 2-sensor sequentioal logic muting function.

Conforming to:

- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery
- Electro-sensitive protective equipment
- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery
- Electro-sensitive protective equipment 
– Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery 
– Safety-related parts of control systems
– Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery 
– Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components.

Safety Relay 



Safety Relay | AUSX - TYPE 2 CONTROL UNIT / PLd

Type 2 control unit to which it is possible to connect from 1 to 4 safety photocells of the Ilion or Ulisse series, thus forming a Type 2 ESPE having a two-channel relay output and the start/restart interlock and FSD monitoring safety functions.
Conforming to:

- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery 
- Electro-sensitive protective equipment
- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery
- Electro-sensitive protective equipment 
– Part 2:Particular requirements for equipment using Active Optoelectronic Protective Device
- EN ISO 13849-1 Safety of machinery
– Safety-related parts of control systems
– Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery 
– Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components. 




Safety Relay




Safety Relay | AUSXM - TYPE 2 / PLd CONTROL UNIT WITH MUTING

Type 2 control unit with Muting to which it is possible to connect from 1 to 4 safety photocells of the Ilion or Ulisse series, thus forming a Type 2 ESPE having a two-channel relay output.
The 2-sensor sequential Muting, start/restart interlock and FSD monitoring safety functions are integrated.


Conforming to:


- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery 
- Electro-sensitive protective equipment
- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery
- Electro-sensitive protective equipment 
– Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery 
– Safety-related parts of control systems 
– Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery 
– Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components.








 












Safety Relay | ADSR0/ADSR0A

Family of safety relays for the interfacing of one integrated light curtain equipped with the EDM (external device monitoring) function, that is of the series Admiral AX and Vision VX.

Two models with Two different type of guided - Contacts Safety Relays:

- ADSR0 with 2NO and 1NC contacts