EOS4 - TYPE 4 INTEGRATED AND COMPACT SAFETY LIGHT CURTAIN

 
Compact, Type 4 - SIL 3 and SILCL 3 - PL e Light Curtain. EOS4, with its small-size housing and minimum dead zone, is ideal for the protection of any tool machine, in particular where space restrictions exist. Its very small dead zone, only present on one side, allows the EOS4 to keep the light curtains resolution if installed on a plan and up to 40 mm if installed at 90° against another EOS unit. EOS4 is available in the X and XHversions, with the integration of start-restart interlock and external contactor monitoring (EDM), as well as in the A and AH versions with automatic restart.

Conforming to:

- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)

- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery-Electro-sensitive protective equipment
- General requirements & tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery
- Electro-sensitive protective equipment
- Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery
- Safety-related parts of control systems
- Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery
- Functional safety related electrical,electronic & programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components
.

 

ADMIRAL - TYPE 4 OPTOELECTRONIC SAFETY BARRIERS

Optoelectronic Safety Barrier is for the protection of workers exposed to risks arising from the use of dangerous machines. Safety Barrier Admiral, with its two safe static outputs, can work without external control units with all the safety functions integrated inside the Emitter and the Receiver complying perfectly with the requirments of the European Standard EN 61496-1 and the International Standard IEC 61496-1-2.
 
Conforming to:

- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery
- Electro-sensitive protective equipment
- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery
- Electro-sensitive protective equipment
– Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery
– Safety-related parts of control systems
– Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery
– Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components.

JANUS - TYPE 4 OPTOELECTRONIC SAFETY BARRIERS

Optoelectronic Safety Barrier is for the protection of workers exposed to risks arising from the use of dangerous machines. The Safety Barrier Janus, with its two safe static outputs, can work without external control units with all the safety functions integrated inside the Emitter and the Receiver complying perfectly with the requirements of the European Standard EN 61496-1 and the International Standard IEC 61496-1-2.
Opto-electronic Safety Barrier for the protection of workers exposed to risks arising from the use of dangerous machines, in situation where the MUTING function is necessary.

The Safety Barrier Janus, with its two safe static outputs, can work without external control units having all the safety functions integrated inside the Emitter and the Receiver and complying perfectly with the
requirements of the European Standard EN 61496-1 and of the International Standard IEC 61496-1-2.

Conforming to:

- 2006/42/CE Machinery Directive

- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery
- Electro-sensitive protective equipment
- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery
- Electro-sensitive protective equipment
– Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery
– Safety-related parts of control systems
– Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery
– Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components.
- ML
and MT versions are fully compliant to the IEC TS 62046 with regard to the geometry of the muting sensors

PHARO - TYPE 3 SIL 2 SAFETY LASER SCANNER

Safety Laser Scanner, suitable for the protection of workers exposed to risks arising from the use of hazardous machines and automated guidance vehicles (AGVs). Pharo creates horizontal or vertical protection areas through programming or self-teaching, up to an amplitude of 190°.

Conforming to:

- 98/37/EEC Machine Directive
- 89/336/EEC Electromagnetic Compatibility Directive
- 73/23/EEC Low Voltage Directive
- EN 61496-1 and IEC 61496-1-3 Electrosensitive protection devices
- IEC 61508 Functional Safety of Electric and Electronic Programmable Devices
                                                                                       

 

 

E0S2 - TYPE 2 INTEGRATED AND COMPACT SAFETY LIGHT CURTAIN

The EOS2, with its small-size housing and minimum dead zone, is ideal for the protection of tool machines, in particular where space restrictions exist.

Its very small dead zone, only present on one side, allows the EOS2 to keep the light curtain’s resolution if installed on a plan and up to 40 mm if installed at 90° against another EOS unit.

EOS2 is available in the X versions, with the integration of start-restart
interlock and external contactor monitoring (EDM), as well as in the A
versions with automatic restart.
 

Conforming to:
 
- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery
- Electro-sensitive protective equipment
- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery
- Electro-sensitive protective equipment
– Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery
– Safety-related parts of control systems
– Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery
– Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components
.

 

VISION - TYPE 2 OPTOELECTRONIC SAFETY BARRIER

Type 2 opto-electronic Safety Barrier for the protection of workers exposed to risks arising from the use of dangerous machines.The Safety Barrier Vision, with its two safe static outputs, can work without external control units with all the safety functions integrated inside the Emitter and the Receiver, in perfect compliance with the requirements of the European Standard EN 61496-1 and of the International Standard IEC 61496-1-2.

Conforming to:

- 2006/42/CE Machinery Directive
- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery
- Electro-sensitive protective equipment

- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive protective
equipment
– Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery
– Safety-related parts of control systems
– Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery
– Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems.
- UL (C+US) for USA and Canada
- ANSI / UL 1998 Software in Programmable Components.

ILION - TYPE 2 SAFETY PHOTOCELL

Safety Photocell for the protection of workers exposed to risks arising from the use of dangerous machines (according to category 2). Used in conjunction with the AU SX or the AU SXM control units, Ilion forms a type 2 photoelectric safety system in compliance with the Standards EN 61496-1 and IEC 61496-1-2.

Conforming to:

- 2006/42/CE Machinery Directive

- 2004/108/CE Electromagnetic Compatibility Directive (EMC)
- 2006/95/CE Low Voltage Directive (LVD)
- IEC/EN 61496-1 Ed. 2.1 Safety of machinery
- Electro-sensitive protective equipment
- General requirements and tests
- IEC/TS 61496-2 Ed. 2 Safety of machinery
- Electro-sensitive protective equipment
– Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices
- EN ISO 13849-1 Safety of machinery
– Safety-related parts of control systems
– Part 1: General principles for design.
- IEC/EN 62061 Safety of machinery
– Functional safety of safety-related electrical, electronic and programmable electronic control systems
- IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems

ULISSE - TYPE 2 PHOTOCELL

Safety Photocell is for the protection of workers exposed to risks arising from the use of dangerous machines. Used in conjunction with the AU S-TWIN or the AU S3M2 control unit, the Ulisse UNC model forms a type 2 photoelectric safety system designed in compliance with the European Standard EN 61496-1 and the International Standard IEC 61496-1-2.

The Ulisse UPC model, provided with a pnp safety output, can be used with a safety plc or with a suitable commercial saefty module.

Conforming to:


- 98/37/EEC Directive on Machines

- 89/336/EEC Electromagnetic Compatibility Directive
- 73/23/EEC Low Voltage Directive
- EN 61496-1-2 and IEC 61496-1-2 Electrosensitive protection devices