Smart Differential Pressure Transmitter APR-2000 ALW
Model: APR-2000ALW SMART DIFFERENTIAL PRESSURE TRANSMITTER
Measuring range: min. 0 ... 4 mbar, max. 0... 16 bar
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
Options:
Digital Profibus PA
Analogue 4...20 mA | 0...5 mA |0...20 mA + Hart Protocol
ATEX Intrinsic Safety
ATEX Explosion Proof
PED Conformity (97/23/EC)
Local Programming Keys | Zero | Range | Shift | Square Root Extraction | Damping
Static Pressure up to 420 Bar
Hastelloy C Diaphragms
SIL 2 Certificate
Marine Certificate DNV
|
|
|
|
|
Data Sheet
|
Manual

|
Smart Differential Pressure Transmitter APRE-2000PD and APRE-2000PZ
Model: Smart differential pressure transmmitter model APRE-2000PD and APRE-2000PZ
Measuring range: min. 0 ... 4 mbar, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1%
4...20 mA HART output
ATEX Intrinsically Safe
Linear or Square root function
Static Pressure Limit up to 420 Bar
Accuracy 0.1% |
|
|
|
|
Data Sheet
|
Manual

|
Differential Pressure Transmitter PRE-28
Model: Differential pressure transmmitter model PRE-28
Measuring range: min. 0 ... 16 mbar, max. 0... 25 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,25%
Overloads up to 320 bar total static pressure
ATEX Intrinsic safety ( Gas and Dust)
Marine certificate DNV
|
|
|
|
|
Data Sheet
|
Manual

|
Differential Pressure Transmitter AS-dP
Model Differential pressure transmmitter model AS-dP
Measuring range: 0 ÷ 1, 0 ÷ 2.5, 0 ÷ 4 ,0 ÷ 6, 0 ÷ 10 ,0 ÷ 16, 0 ÷ 25 bar
Output signal: 4 ÷ 20 mA or 0 ÷ 10 V
Accuracy: 0,4%
|
|
|
|
|
Data Sheet
|
Manual

|
Smart Differential Pressure Transmitter Low Ranges Model APR-2000G ALW
Model: Smart differential pressure transmitter for low ranges model APR-2000G ALW
Programing: Local Keys
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Digital PROFIBUS PA signal
Programmable range, zero shift, damping ratio and Characteristic
with local panel keys
Selectable linear or radical conversion characteristic
ATEX Intrinsic safety
|
|
|
|
|
Data Sheet
|
Manual

|
Smart Pressure Transmitter Low Ranges Model APRE-2000G
Model: Smart pressure transmitter for low ranges APRE-2000G
Measuring range: Min. 0 ... 0,2 mbar, max. 0... 100 mbar
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Process connection: To fit 6mmx1mm pipe, mounted with a valve manifold
Programmable range, zero shift, damping ratio and characteristic
ATEX Intrinsic safety (only APRE-2000G/PD, APRE-2000G/PZ
|
|
|
|
|
Data Sheet
|
Manual

|
Smart Differential Pressure Transmitter APRE-2200 with Remote Diaphragm Seals
Model: APRE-2200 Smart differential pressure transmmitter with remote diaphragm seals
Measuring range: min. 0 ... 0,1mH2O, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART; Profibus PA
Accuracy: 0,1%
Several applications, including hydrostatic measurement of
levels in closed tanks, density and phase boundaries
Ability to configure measuring range locally
ATEX certificates (intrinsic safety, explosion proof)
Fully welded active measuring element which guarantees Tightness of fill oil system
|
|
|
|
|
Data Sheet
|
Manual

|
|
|