You are here:   Products > Transducers > Power Transducers
Register   |  Login

P11P - Programmable transducer for active power with analog output

P11P - Analog measuring transducer is designed for conversion into a standard analog signal active power in 1-phase network. Output signal is galvanically isolated from the input signal and supply.


Input: 1 A (X/1 A), 5 A (X/5A), 57,7...690 V, X/100V
Output: ± 0...4/20 mA, ± 0...10V
Mounting : DIN Rail
External dimensions: 45 x 120 x 100mm
P11P - Analog measuring transducer

 
Data Sheet
P11P - Analog measuring transducer datasheets
 Manual
P11P - Analog measuring transducer manuals


P13P - Analog transducer for active power with analog output

P13P - Analog measuring transducer is designed for conversion into a standard analog signal active power in 3-phase 3-wire network. Output signal is galvanically isolated from input signal and supply.


input: 1 A (X/1 A), 5 A (X/5A), 57,7...690 V, X/100 V
Output:± 0/4...20mA, ±0...10V
Mounting: DIN rail
External dimensions: 45 x 120 x 100mm
p13p POWER TRANSDUCERS


Data Sheet
P13P - Analog measuring transducer datasheets
 Manual
P13P - Analog measuring transducer manuals


P13B - Analog transducer for reactive power with analog output

P13B Analog measuring transducer type is designed for conversion into a standard analog signal reactive power in 3-phase network. Output signal is galvanically isolated from the input signal and supply.

Input: 1 A (X/1 A), 5 A (X/5A), 57,7...690 V, X/100V
Output: ± 0...4/20 mA, ± 0...10V
Mounting : DIN rail
External dimensions: 45 120 x 100mm
p13b POWER TRANSDUCERS


Data Sheet
P13B Analog measuring transducer datasheets
 Manual
P13B Analog measuring transducer manuals

P43 - Programmable transducer of power network parameters


P43 Programmable transducer for power network parameters is designed for the conversion of 3-phase, 3 or 4-wire power network parameters, in balanced or unbalanced systems.

Inputs signals:
Current: 1A or 5A
Voltage: 100V or 400V
Outputs:
4 relays (signaling measured quantity overflows), without analog outputs
2 relays, 2 analog outputs
4 analog outputs, without relay outputs, Pulse output (control of 3-phase active energy consumption), RS-485 and USB interfaces with Modbus protocol, Built-in memory for the 15 minutes’ power profile, Storage of maximal and minimal values, Galvanic isolation, Programmable current and voltage transformer ratios, Transducer programming realized by means of a free delivered LPConfig software.
Overall dimensions: 90 x 120 x 100 mm.
p43 transducer of power network parameters


Data Sheet
p43 transducer of power network parameters datasheets
 Manual
p43 transducer of power network parameters manuals


P10 | P10A - Power network parameter transducers


Power network parameter transducer P10 and P10A type are designed to measure:
power network parameters in 3-phase 3-wire or 3-phase 4-wire, balanced or unbalanced network systems e.g.: rms a.c. voltage and a.c. current, active, reactive and apparent power, active, reactive and apparent energy, different power factors, frequency, average active power (e.g. 15 min), cosj, tgj,
harmonics, up to 25-th,THD factor.


Transducer enables monitoring of the maximal power, measurement of max. and min. values with a time marker.
Transducer is commonly used in computer systems, e.g. with LUMEL-ENERGY program.
Input: programmable
100 V, 400 V,1 A, 5 A a.c.,
3 inputs to control energy counter tariffs,


Output:
P10 type - 4 relay outputs, 4 analog outputs 0...20mA, 4...20mA
P10A type - 4 relay outputs, 4 analog outputs +/-5mA and on request +/-20mA,
digital output RS485 - with MODBUS protocol,
1 or 3 pulse passive output,
Supply: 85...253 V d.c. or a.c 40...400Hz,
Display field: LCD 2 x 16 signs.
External dimensions: 152 x 73 x 118mm
Power network parameter transducer P10 and P10A


Data Sheet
Power network parameter transducer P10 and P10A datasheets
Manual
Power network parameter transducer P10 and P10A manuals